1746 NI4 Wiring Diagram

The 1746 NI4 is a signal conditioning module that is used to condition the input signals from sensors and other devices. These signals are then converted into an analog signal that can be used by a processor or controller to perform various functions. The wiring of the 1746 NI4 is an essential part of the installation process. In this article, we will provide you with a detailed wiring diagram for the 1746 NI4 module, along with frequently asked questions and tables to help you better understand the wiring process.

Overview of 1746 NI4 Wiring Diagram

The 1746 NI4 module is designed to be used with a range of devices and sensors, including thermocouples, RTDs, and voltage and current inputs. The module provides signal conditioning for these inputs, which are then converted into an analog input signal that can be used by a processor or controller.

The wiring diagram for the 1746 NI4 module is relatively simple, and it involves connecting the input signals to the appropriate terminals on the module. The diagram includes four input channels, with each channel capable of conditioning a single input signal from a device or sensor. The wiring diagram also includes connections for the power supply and for the output signal to the processor or controller.

1746 NI4 Wiring Diagram Table

Terminal Function
1 Input 1: Positive
2 Input 1: Negative
3 Input 2: Positive
4 Input 2: Negative
5 Input 3: Positive
6 Input 3: Negative
7 Input 4: Positive
8 Input 4: Negative
9 Power Supply: +24V DC
10 Power Supply: 0V DC
11 Analog Output: +10V DC
12 Analog Output: -10V DC

FAQs about 1746 NI4 Wiring Diagram

What is the purpose of the 1746 NI4 module?

The 1746 NI4 module is a signal conditioning module that is used to condition input signals from sensors and devices. The module then converts these input signals into an analog signal that can be used by a processor or controller for various functions.

What devices and sensors can the 1746 NI4 module be used with?

The 1746 NI4 module can be used with a range of devices and sensors, including thermocouples, RTDs, and voltage and current inputs.

What is the input range for the 1746 NI4 module?

The input range for the 1746 NI4 module varies depending on the type of input signal being conditioned. The input range can be adjusted using the DIP switches on the module.

How do I connect the inputs to the 1746 NI4 module?

To connect inputs to the 1746 NI4 module, simply connect the positive and negative leads from the device or sensor to the appropriate terminals on the module. The wiring diagram provided in this article shows the appropriate connections for each input channel.

What is the output signal range for the 1746 NI4 module?

The output signal range for the 1746 NI4 module is between +10V DC and -10V DC.

Conclusion

The wiring diagram for the 1746 NI4 module is a crucial part of the installation process. By following the wiring diagram provided in this article, you can ensure that your module is wired correctly, and that it is functioning properly. If you have any further questions or concerns about the wiring process, be sure to consult the manufacturer’s instructions or contact a professional for assistance.